IDP Library - Coop Canaletto
Reference person: | Marta Avantaggiato (EURAC) |
---|---|
Simulation report: |
Reference building
Name: | Coop Canaletto |
---|---|
Location: | Modena (IT) |
General data
Urban context: | urban |
---|---|
Climate: | CD |
Building: | purpose-built |
Year of construction: | |
Year of retrofit: | 2016 |
GLA before retrofit [m²]: | 1102 |
GLA after retrofit [m²]: | |
Shopping centre size: | Small |
Shopping centre sub-typology: | neighbourhood/community |
Food store format: | supermarket |
Food store vending area [m²]: | 1224 |
Tenants vending area [m²]: | 1900 |
Common areas and galleries [m²]: | 521 |
Nr of opening hours per day [h/d]: | 12.0 |
Nr of opening days per week [d/w]: | 7 |
Nr of closing days per year (because of holidays) [d/y]: | 6 |
Building features
Centre design: | semi-enclosed |
---|---|
Shape: | 0.5 |
Orientation: | NE/SW |
Number of levels above ground: | 1 |
Number of underground levels: | 1 |
Parking location: | external area |
Number of parking levels: | 1 |
Biologically active area [%]: | 0% |
Perimeter
Wall structure: | masonry |
---|---|
Wall insulation location: | none |
Wall insulation material: | natural |
Wall U-value [W/m²K]: | 1.840 |
WWR - north [%]: | |
WWR - east [%]: | |
WWR - south [%]: | |
WWR - west [%]: | |
Windows U-value [W/m²K]: | 1.40 |
Window glazing g-value [-]: | 1 |
Basement/Floor structure: | other |
Basement/Floor insulation location: | none |
Basement/Floor insulation material: | natural |
Basement/Floor thermal transmittance [W/m²K]: | 1.730 |
Roof structure: | other |
Roof insulation location: | none |
Roof insulation material: | mineral |
Roof U-value [W/m²K]: | 1.640 |
Vehicle accessible roof covering [%]: | 0% |
Green roof covering [%]: | 0% |
ST roof covering [%]: | 0% |
PV roof covering [%]: | 0% |
SRR [%]: | |
Skylight U-value [W/m²K]: | |
Skylight glazing g-value [-]: |
Technical room
Location: | underground |
---|---|
BMS lighting [Y/N]: | N |
BMS natural ventilation [Y/N]: | N |
BMS HVAC [Y/N]: | N |
BMS refrigeration [Y/N]: | N |
BMS solar thermal system [Y/N]: | N |
BMS electric storage [Y/N]: | N |
Ventilation specific power [Wh/m³]: | 0.70 |
Heat recovery thermal efficiency [%]: | |
SPF heating [-]: | 2.36 |
SPF cooling [-]: | 2.36 |
Common areas
Installed lighting power density [W/m²]: | |
---|---|
Installed electric equipment power density [W/m²]: |
Tenants
Installed lighting power density [W/m²]: | |
---|---|
Installed electric equipment power density [W/m²]: |
Food store
Installed lighting power density [W/m²]: | 40-45 |
---|---|
Installed electric equipment power density [W/m²]: | 5 |
Primary energy consumption
Lighting [kWh/m²-y]: | 461 |
---|---|
Refrigeration [kWh/m²-y]: | 667 |
Plug loads [kWh/m²-y]: | 16 |
HVAC [kWh/m²-y]: | 162 |
Tot. primary energy [kWh/m²-y]: | 1306 |
Carbon emissions
Carbon emissions [tonCO2eq]: | 398 |
---|
Inefficiencies
Envelope ineff.1: | Inefficient insulation |
---|---|
Envelope ineff. 2: | No insulated external doors |
Envelope ineff. 3: | |
Lighting ineff.1: | Inefficient lamp technology and inefficient luminaires |
Lighting ineff. 2: | Lack of daylight entries |
Lighting ineff. 3: | |
Refrigeration ineff. 1: | Open freezers and refrigerators |
Refrigeration ineff. 2: | No night blinds on open cooling cabinets |
Refrigeration ineff. 3: | |
HVAC_general general ineff.: | |
HVAC_general general ineff.: | |
HVAC_heating heating ineff.: | |
HVAC_heating heating ineff.: | |
HVAC_cooling cooling ineff.: | |
HVAC_cooling cooling ineff.: | |
HVAC_ventilation ventilation ineff.: | |
HVAC_ventilation ventilation ineff.: |
Retrofit solution set I
Solution set I ID: | 4 |
---|---|
Primary energy consumption [kWh/m²-y]: | 584 |
Primary energy savings [%]: | 55% |
Carbon emissions tonCO2eq: | 182 |
Carbon emission savings [%]: | 55% |
Investment cost [M€]: | 0.593 |
Operational energy cost [k€/year]: | 17 |
Pay-back time [years]: | 8.8-15 |
Net Present Value [M€]: | 1035 |
Maintenance cost [k€/year]: | 13 |